>>Product>>TEST MEASURE MONITOR >>FLUKE >> MULTIMETERS      
FLUKE FLUKE-117/PRV240 DIGITAL MULTIMETER AND PROVING UNIT KIT
Fluke FLUKE-117/PRV240 Offers
The digital multimeter includes integrated non-contact voltage detection to help get the job done faster

Ideal for applications such as commercial buildings, hospitals, and schools, this multimeter comes equipped with True-RMS. This instrument helps prevent false readings caused by ghost voltage due to integrated non-contact voltage detection, Auto Volts, and LoZ functions. Additionally, this tool comes supplied with min/max/average readings and measures frequency, capacitance, and an easy-to-use interface.

Engineered and tested with your safety on the job in mind

Tested for safe use in CAT III 600 V environments and designed in several features to make it easier and faster for you to get the measurements you need.

Features

VoltAlert™ technology for non-contact voltage detection
AutoVolt automatic ac/dc voltage selection
LoZ: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True-rms for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30 seconds)
Resistance, continuity, frequency and capacitance
Min/max/average to record signal fluctuations
Compatible with optional magnetic hanger (ToolPak™) for hands free operation
Accurate and easy-to-use
Provides low input impedance to help prevent false readings due to ghost voltage
CAT III 600 V safety rated
Applications

Commercial buildings
Hospitals
Schools
Fluke PRV240 Proving Unit

Reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.

Features

Sources both AC and DC steady-state voltage - supplies 240 V DC/AC
A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
Long battery life - 5000 tests per set of four AA batteries
Test before touch

Provides a safe method to verify that your electrical test tool is operating properly before you conduct further tests. The concept of "Test Before Touch" (TBT) or three point test method involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.

Designed for safety and compliance

Safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.

Applications

Test and measurement

Fluke FLUKE-117/PRV240 Specifications
Multimeter
DC millivolts Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ±0.5% of reading + 2 counts
DC Volts Range: 6.000 V, 60.00 V, 600.0 V
Resolution: 0.001 V, 0.01 V, 0.1 V
Accuracy ±0.5% of reading + 2 counts
Continuity Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on <20 Ω off> 250 Ω; detects opens or shorts of 500 µs or longer
Maximum voltage between any terminal and earth ground: 600 V
Surge Protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A Input 11 A, 1000 V FAST Fuse
Display Digital: 6000 counts, updates 4/sec
Bar Graph 33 segments, updates 32/sec
Temperature Operating: 14 to 122°F (-10 to 50°C)
Storage: -40 to 140°F (-40 to 60°C)
Proving Unit
Output Voltage: 240 V AC RMS or DC ±10 % ≥1 MΩ
Output Voltage: LoZ >3 kΩ load 60 V AC typical; 50 V AC RMS minimum
LED Power Indicator Turns on when output voltage is present
Battery 4 x AA Alkaline batteries NEDA (24 A IEC LR03)
Battery Life 5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load
Operating Temperature 14 to 122°F (-10 to 50°C)
Operating Humidity 0 to 90% (0 to 35°C)
Operating Altitude 6561.68' (2000 m)
Safety IEC61010-1, IEC61010-2-030
Certification CSA-CUS, CE
Dimensions 4.6 x 2.9 x 1.1" (11.7 x 7.4 x 2.8 cm)
Weight 8 oz (0.23 kg) includes batteries